CONTACTOR
SQUARE D/TELEMECANIQUE
LC1D09G7
N22316 9A 127V CONTACTOR
NON REVERSING; 3 POLE; 0.5 HP AT 115 VAC, 1 HP AT 230 VAC 1 PHASE; 2 HP AT 200/230 VAC, 5 HP AT 460 VAC, 7.5 HP AT 575 VAC 3 PHASE; INDUCTIVE CURRENT 9 AMPERE (AC-3); RESISTIVE CURRENT 20 AMPERE (AC-1); COIL VOLTAGE 120 VAC AT 50/60 HZ; AUXILIARY CONTACT 1NO-1NC; OPEN; IEC CONSTRUCTION STANDARD; APPROVAL UL, CSA, ASE, BV, DEMKO, DNV, FI, NEMKO, RINA, RRS, SEMKO; LC1D MODEL

Show all:  Definite Purpose Contactors - Iec Contactors

 Spec Sheet   |   More Details
2
CONTACTOR
SQUARE D/TELEMECANIQUE
LC1D32G7
R22316 32A 127V CONTACTOR
NON REVERSING; 3 POLE; 2 HP AT 115 VAC, 5 HP AT 230 VAC 1 PHASE; 10 HP AT 200/230 VAC, 20 HP AT 460 VAC, 30 HP AT 575 VAC 3 PHASE; INDUCTIVE CURRENT 32 AMPERE (AC-3); RESISTIVE CURRENT 50 AMPERE (AC-1); COIL VOLTAGE 120 VAC AT 50/60 HZ; AUXILIARY CONTACT 1NO-1NC; OPEN; IEC CONSTRUCTION STANDARD; APPROVAL UL, CSA, ASE, BV, DEMKO, DNV, FI, NEMKO, RINA, RRS, SEMKO; LC1D MODEL

Show all:  Definite Purpose Contactors - Iec Contactors

 Spec Sheet   |   More Details
4
DEFINITE PURPOSE CONTACTOR
SQUARE D/TELEMECANIQUE
8910DPA33V06
R21343 480V CONTACTOR
NON REVERSING; 3 POLE; 2 HP AT 115 VAC 1 PHASE, 5 HP AT 230 VAC 1 PHASE, 10 HP AT 230 VAC 3 PHASE, 15/20 HP AT 460/575 VAC 3 PHASE; 30 AMPERE CURRENT RATING; RESISTIVE CURRENT 40 AMPERE; COIL VOLTAGE 440 VAC AT 50 HZ, 480 VAC AT 60 HZ; AUXILIARY CONTACT 3NO; OPEN ENCLOSURE; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA, CE; 8910 MODEL; INCLUDES BINDING HEAD SCREW TERMINAL WITH QUICK CONNECT; LOCKED ROTOR RATING 180 AMPERE AT 230 VAC, 150 AMPERE AT 460 VAC, 120 AMPERE AT 575 VAC

Show all:  Definite Purpose Contactors

 Spec Sheet   |   More Details
2
DEFINITE PURPOSE CONTACTOR
SQUARE D/TELEMECANIQUE
8910DPA33V09
R21343 208/240V CONTACTOR
NON REVERSING; 3 POLE; 2 HP AT 115 VAC 1 PHASE, 5 HP AT 230 VAC 1 PHASE, 10 HP AT 230 VAC 3 PHASE, 15/20 HP AT 460/575 VAC 3 PHASE; 30 AMPERE CURRENT RATING; RESISTIVE CURRENT 40 AMPERE; COIL VOLTAGE 220 VAC AT 50 HZ, 208 TO 240 VAC AT 60 HZ; AUXILIARY CONTACT 3NO; OPEN ENCLOSURE; NEMA CONSTRUCTION STANDARD; APPROVAL UL, CSA, CE; 8910 MODEL; INCLUDES BINDING HEAD SCREW TERMINAL WITH QUICK CONNECT; LOCKED ROTOR RATING 180 AMPERE AT 230 VAC, 150 AMPERE AT 460 VAC, 120 AMPERE AT 575 VAC

Show all:  Definite Purpose Contactors

 Spec Sheet   |   More Details
5
THERMAL UNIT
SQUARE D/TELEMECANIQUE
B11.5
N21781 HTR ELEMENT
CLASS 20, STANDARD TRIP; MOTOR FLA 14.06 TO 15.85 AMPERE (1 THERMAL UNIT); 7, 8 NEMA SIZE; PLUG IN MOUNTING; STANDARD PACKAGE 6; USED ON OVERLOAD RELAY

Show all:  Motor Control Starters, Etc - Thermal Overld Heater Elements

 Spec Sheet   |   More Details
9
MAGNETIC CONTACTOR AND STARTER CONTACT KIT
SQUARE D/TELEMECANIQUE
9998SL3
R21756 CONTACT PARTS KIT
SIZE NEMA 1, NEMA 1P; 3 POLE; USED ON SC/SM SERIES MAGNETIC CONTACTOR/STARTER; 9998 MODEL; KIT CONTAINS MOVABLE AND STATIONARY CONTACTS, CONTACT SPRING, ADDITIONAL HARDWARE

Show all:  Starter Accessories

 Spec Sheet   |   More Details
2
CONTACTOR
SQUARE D/TELEMECANIQUE
LC1D09BD
R22345 600V 9A CONTACTOR
NON REVERSING; 3 POLE; 0.5 HP AT 115 VAC, 1 HP AT 230 VAC 1 PHASE; 2 HP AT 200/230 VAC, 5 HP AT 460 VAC, 7.5 HP AT 575 VAC 3 PHASE; INDUCTIVE CURRENT 9 AMPERE (AC-3); RESISTIVE CURRENT 20 AMPERE (AC-1); COIL VOLTAGE 24 VDC; AUXILIARY CONTACT 1NO-1NC; OPEN; IEC CONSTRUCTION STANDARD; APPROVAL UL, CSA, ASE, BV, DEMKO, DNV, FI, NEMKO, RINA, RRS, SEMKO; LC1D MODEL

Show all:  Definite Purpose Contactors - Iec Contactors

 Spec Sheet   |   More Details
2
NEMA STARTER AND CONTACTOR AUXILIARY CONTACT
SQUARE D/TELEMECANIQUE
9999SX6
R21761 INTERLOCK KIT
AUXILIARY CONTACT; SIDE MOUNTING LOCATION; CONTACT CONFIGURATION 1NO; CONTACT RATING 120/600 VAC 10 AMPERE; 00 TO 7 NEMA SIZE; USED ON CONTACTOR/STARTER; 9999 MODEL

Show all:  Starter Accessories

 Spec Sheet   |   More Details
2
CONTACTOR
SQUARE D/TELEMECANIQUE
LC1D12G7
R22316 12A 127V CONTACTOR
NON REVERSING; 3 POLE; 1 HP AT 115 VAC, 2 HP AT 230 VAC 1 PHASE; 3 HP AT 200/230 VAC, 7.5 HP AT 460 VAC, 10 HP AT 575 VAC 3 PHASE; INDUCTIVE CURRENT 12 AMPERE (AC-3); RESISTIVE CURRENT 25 AMPERE (AC-1); COIL VOLTAGE 120 VAC AT 50/60 HZ; AUXILIARY CONTACT 1NO-1NC; OPEN; IEC CONSTRUCTION STANDARD; APPROVAL UL, CSA, ASE, BV, DEMKO, DNV, FI, NEMKO, RINA, RRS, SEMKO; LC1D MODEL

Show all:  Definite Purpose Contactors - Iec Contactors

 Spec Sheet   |   More Details
2
MANUAL STARTER
SQUARE D/TELEMECANIQUE
GV2ME08
R22367 4A 600V MAN STARTER
NON REVERSING, MOTOR PROTECTOR; 3 PHASE RATING 3/4 HP AT 208/240 VAC, 1 HP AT 240 VAC, 2 HP AT 480 VAC, 3 HP AT 600 VAC; 1 PHASE RATING 1/8 HP AT 120 VAC, 1/4 HP AT 208 VAC, 1/3 HP AT 240 VAC; 4 AMPERE (IEC THERMAL CURRENT) AT 690 VAC CURRENT RATING; 3 POLE; IP20, RAIL ENCLOSURE; PUSHBUTTON OPERATOR; OVERLOADS BIMETALLIC AMBIENT TEMPERATURE COMPENSATED CLASS 10 THERMAL SETTING 2.5 TO 4 AMPERE; IEC CONSTRUCTION STANDARD; TESYS[R] BRAND; GV2ME MODEL; APPROVAL UL 508, CSA C22.2, CE, GL, GOST, RINA; WITH SCREW CLAMP TERMINAL

Show all:  Manual Starters

 Spec Sheet   |   More Details
2
THERMAL UNIT
SQUARE D/TELEMECANIQUE
B25.0
N21781 HTR ELEMENT
CLASS 20, STANDARD TRIP; MOTOR FLA 28 TO 31.7 AMPERE (1 THERMAL UNIT); 1, M-1, M-1P NEMA SIZE; PLUG IN MOUNTING; STANDARD PACKAGE 6; USED ON OVERLOAD RELAY

Show all:  Motor Control Starters, Etc - Thermal Overld Heater Elements

 Spec Sheet   |   More Details
3
THERMAL UNIT
SQUARE D/TELEMECANIQUE
B36.0
R21781 HTR ELEMENT
CLASS 20, STANDARD TRIP; MOTOR FLA 39 TO 44.5 AMPERE (1 THERMAL UNIT); 1, 2, M-1, M-1P NEMA SIZE; PLUG IN MOUNTING; STANDARD PACKAGE 6; USED ON OVERLOAD RELAY

Show all:  Motor Control Starters, Etc - Thermal Overld Heater Elements

 Spec Sheet   |   More Details
3
AUXILIARY CONTACT BLOCK
SQUARE D/TELEMECANIQUE
LADN11
R22341 IEC AUX CONTACT BLOCK
AUXILIARY CONTACT; FRONT/RIGHT MOUNTING LOCATION; CONTACT CONFIGURATION 1NO-1NC; CONTACT RATING 600 VAC 10 AMPERE; SCREW CLAMP TERMINAL; APPROVAL UL, CSA, CE; USED ON LC1F SERIES CONTACTOR

Show all:  Contactor Accessories

 Spec Sheet   |   More Details
4
MANUAL STARTER
SQUARE D/TELEMECANIQUE
GV2ME10
R22367 6.3A 600V MAN STARTER
NON REVERSING, MOTOR PROTECTOR; 3 PHASE RATING 3/4 HP AT 120 VAC, 1 HP AT 208 VAC, 1 1/2 HP AT 240 VAC, 3 HP AT 480 VAC, 5 HP AT 600 VAC; 1 PHASE RATING 1/4 HP AT 120 VAC, 1/2 HP AT 208/240 VAC; 6.3 AMPERE (IEC THERMAL CURRENT) AT 690 VAC CURRENT RATING; 3 POLE; IP20, RAIL ENCLOSURE; PUSHBUTTON OPERATOR; OVERLOADS BIMETALLIC AMBIENT TEMPERATURE COMPENSATED CLASS 10 THERMAL SETTING 4 TO 6.3 AMPERE; IEC CONSTRUCTION STANDARD; TESYS[R] BRAND; GV2ME MODEL; APPROVAL UL 508, CSA C22.2, CE, GL, GOST, RINA; WITH SCREW CLAMP TERMINAL

Show all:  Manual Starters

 Spec Sheet   |   More Details
1
MANUAL STARTER
SQUARE D/TELEMECANIQUE
GV2ME07
R22367 MANUAL STARTER 600VAC
NON REVERSING, MOTOR PROTECTOR; 3 PHASE RATING 1/2 HP AT 208/240 VAC, 1 HP AT 480 VAC, 1 1/2 HP AT 600 VAC; 1 PHASE RATING 1/6 HP AT 208/240 VAC; 2.5 AMPERE (IEC THERMAL CURRENT) AT 690 VAC CURRENT RATING; 3 POLE; IP20, RAIL ENCLOSURE; PUSHBUTTON OPERATOR; OVERLOADS BIMETALLIC AMBIENT TEMPERATURE COMPENSATED CLASS 10 THERMAL SETTING 1.6 TO 2.5 AMPERE; IEC CONSTRUCTION STANDARD; TESYS[R] BRAND; GV2ME MODEL; APPROVAL UL 508, CSA C22.2, CE, GL, GOST, RINA; WITH SCREW CLAMP TERMINAL

Show all:  Manual Starters

 Spec Sheet   |   More Details
2