CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM120
N00046 SP-120/240V-20A CB
COMMON TRIP, THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
153
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM230
N00046 2P-120/240V-30A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
51
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM260
N00046 2P-120/240V-60A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
71
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM240
N00046 2P-120/240V-40A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
41
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO120
N00004 SP-120/240V-20A CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 20 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
178
SQUARE D/TELEMECANIQUE
HOM120PDF
R06301 MINI CIRCUIT BREAKER

Show all:  Arc Fault Afci Plug-In Circuit Breakers

 More Details
49
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM220
N00046 2P-120/240V-20A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
15
SQUARE D/TELEMECANIQUE
HOM120PCAFI
R06301 MINI CIRCUIT BREAKER

Show all:  Arc Fault Afci Plug-In Circuit Breakers

 More Details
88
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM250
N00046 2P-120/240V-50A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
36
HANDLE PADLOCK ATTACHMENT
SQUARE D/TELEMECANIQUE
HOM2PALA
R00150 CKT BRKR HANDLE PADLK
PADLOCKABLE; 2 POLE; ON/OFF LOCKING PROVISION; USED ON HOM SERIES CIRCUIT BREAKER; HOM MODEL

Show all:  Circuit Breaker Accessories

 Spec Sheet   |   More Details
8
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM115
N00046 SP-120/240V-15A CB
COMMON TRIP, THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1 INCH W X 2.98 INCH D X 3.13 INCH H; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
37
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO230
N00004 2P-120/240V-30A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 30 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
25
SQUARE D/TELEMECANIQUE
HOM4080M200PC
R00045 LD-CNTR BOX&INT

Show all:  Single Phase Convertible Load Centers

 More Details
15
CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
HOM2100
R00146 2P-120/240V-100A CB
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON HOMELINE[R] LOAD CENTER; HOM MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
1
LOAD CENTER LUG KIT
SQUARE D/TELEMECANIQUE
LK100AN
R00102 LD CNTR NEUTRAL LUG
GROUND/NEUTRAL LUG; 6 TO 2/0 AWG CONDUCTOR; CONDUCTOR MATERIAL ALUMINUM/COPPER; USED ON CLASS 1130 QO[R] LOADCENTER

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
10
* E=Each, C=100, M=1000